• China Fire Resistance Test Equipment , Wire Testing Equipment IEC 60331 For Line / Cable wholesale
    ...IEC 60331 Line and Cable Fire Resistance Testing Equipment Introduction: Fire Resistance Tester is used in test conditions where the basic flame temperature is at least 750ºC and tests the cable exposed to the flame that needs to maintain the circuit integrity. Standard: IEC 60331 - Test for electric cables under fir conditions - Circuit integrity IEC 60331 Part 11 - Apparatus - Fire alone at a flame temperature of at least 750˚C IEC more
    Brand Name:YUYANG
    Model Number:YY429
    Place of Origin:China

    Fire Resistance Test Equipment , Wire Testing Equipment IEC 60331 For Line / Cable

  • China 0.6/1kV Low Smoke Zero Halogen Cable IEC 60502, IEC 60287 IEC 60331 Standard wholesale
    0.6/1kV Low Smoke Zero Halogen Cable IEC 60502, IEC 60287 IEC 60331 Standard Low Smoke Zero Halogen Cable Constructions 1. Copper or aluminum conductor 2. PE or XLPE insulation 3. Filler 4. Wrapping ... more
    Brand Name:SHAN CABLE
    Model Number:WDZA-YJY WDZ-YJE
    Place of Origin:SHANGHAI CHINA

    0.6/1kV Low Smoke Zero Halogen Cable IEC 60502, IEC 60287 IEC 60331 Standard

  • China IEC 60331-21 Fire Testing Equipment Wire Flame Small Lab Oven Without Combustion Chamber wholesale
    IEC60331-21 Wire Flame Test Chamber Standards IEC 60331-21 Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV Specification 2. Cable and cable ... more
    Brand Name:SKYLINE
    Model Number:SL-IEC33
    Place of Origin:China

    IEC 60331-21 Fire Testing Equipment Wire Flame Small Lab Oven Without Combustion Chamber

    SKYLINE INSTRUMENTS CO.,LTD
    [Guangdong,China]
  • China 0.6/1kV Fire Resistant Cable Size 1.5sqmm ~ 800sqmm Four Core IEC 60331 wholesale
    0.6/1kV Single Core Fire Resistant Power Cable 1.5 sqmm ~ 800 sqmm IEC 60331 It can be widely used as power lines, control lines and signal transmission lines for electrical appliances, instruments, electronic equipment and automation ... more
    Brand Name:HOLD-ONE
    Place of Origin:China

    0.6/1kV Fire Resistant Cable Size 1.5sqmm ~ 800sqmm Four Core IEC 60331

  • China IEC 60331 Fire Resistance Testing Machine with Shock and Water for Cable Test wholesale
    ... with shock where the test condition is based upon flame with a controlled heat output corresponding to a temperature of at least 750˚C or fire with shock at a temperature of at least 830 °C. ​IEC 60331 Test for electric cables under fire more
    Brand Name:AI
    Model Number:CFRTM
    Place of Origin:CHINA

    IEC 60331 Fire Resistance Testing Machine with Shock and Water for Cable Test

  • China IEC 60331 Fire Retardant Testing Machine For Electric Cables wholesale
    IEC 60331, BS 6387 Electric Cables Under Fire Conditions Circuit integrity Testing Machine EN 50200 Description: - Fire-resistant ... more
    Brand Name:Daxian
    Model Number:DX8422
    Place of Origin:China

    IEC 60331 Fire Retardant Testing Machine For Electric Cables

  • China Low Voltage IEC 60331 Fire Resistant Cable 1- 5 Cores Excellent Electrical Properties wholesale
    1 Core - 5 Cores Copper Fire Resistant Cable IEC Standard LV FRC cable Product Description Construction Application: Crosslinked polyethylene insulated power cables have excellent thermal-mechanical properties, excellent electrical properties and chemical ... more
    Brand Name:CHINT
    Model Number:N-YJV
    Place of Origin:CHINA

    Low Voltage IEC 60331 Fire Resistant Cable 1- 5 Cores Excellent Electrical Properties

  • China IEC 60331&BS6387 Cable Circuit Integrity Under Fire Conditions Apparatus wholesale
    ... with shock where the test condition is based upon flame with a controlled heat output corresponding to a temperature of at least 750˚C or fire with shock at a temperature of at least 830 °C. ​IEC 60331 Test for electric cables under more
    Brand Name:AIC
    Model Number:CFRTM
    Place of Origin:CHINA

    IEC 60331&BS6387 Cable Circuit Integrity Under Fire Conditions Apparatus

  • China IEC 60331-21 Fire Testing Equipment Wire Flame Small Lab Oven Without Combustion Chamber wholesale
    IEC60331-21 Wire Flame Test Chamber Standards IEC 60331-21 Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV Specification 2. Cable and cable ... more
    Brand Name:SKYLINE
    Model Number:SL-IEC33
    Place of Origin:China

    IEC 60331-21 Fire Testing Equipment Wire Flame Small Lab Oven Without Combustion Chamber

    Skyline Instruments Co.,LTD
    [Guangdong,China]
  • China 2x2.5mm2 IEC 60331 Fire Resistant Cable Copper Metallic Sheath wholesale
    2 Core Fire Resistant Cable Mineral Insulated Bare Copper Class 2 Conductor Fire Resistant Cable is designed for aboveground applications. Engineered to replace conduit and wire applications, this all-in-one cable assembly offers fewer installation steps... more
    Brand Name:OEM
    Place of Origin:China

    2x2.5mm2 IEC 60331 Fire Resistant Cable Copper Metallic Sheath

  • China CFRT IEC 60331 Electric Cable Fire Resistance Testing Equipment wholesale
    IEC60331 Electric Cable Fire Resistance Testing Equipment -- Model CFRT Introduction: CFRT IEC60331 Electric Cable Fire Resistance Testing Equipment is used for testing cables required to maintain circuit integrity when subject to fire alone or fire with ... more
    Brand Name:LAB TECH
    Model Number:CFRT
    Place of Origin:China

    CFRT IEC 60331 Electric Cable Fire Resistance Testing Equipment

  • China CFRT IEC 60331 Electric Cable Fire Resistance Testing Equipment wholesale
    IEC60331 Electric Cable Fire Resistance Testing Equipment -- Model CFRT Introduction: CFRT IEC60331 Electric Cable Fire Resistance Testing Equipment is used for testing cables required to maintain circuit integrity when subject to fire alone or fire with ... more
    Brand Name:LAB TECH
    Model Number:CFRT
    Place of Origin:China

    CFRT IEC 60331 Electric Cable Fire Resistance Testing Equipment

  • China IEC 60331 Movable Cable Integrity Flammability Testing Equipment / Combustion Chamber wholesale
    IEC 60331 Movable Cable Integrity Flammability Testing Equipment / Combustion Chamber 1. Description The tester is designed according to GB/T 19216.11-2003/IEC 60331-11:1999 "Line integrity test of cables and optical cables under flame conditions Part 11: test apparatus - individual fire supply with flame temperature not lower than 750℃". It fully conforms to GB/T 19216.21-2003/IEC 60331... more
    Brand Name:ZONSKY
    Model Number:ZY6014J
    Place of Origin:DONGUAN CHINA

    IEC 60331 Movable Cable Integrity Flammability Testing Equipment / Combustion Chamber

    ZONSKY INSTRUMENT CO.,LTD
    [Guangdong,China]
  • China Iec 60331 Fire Resistant Cable Copper Conductor For Signaling / Mining wholesale
    Iec 60331 Fire Resistant Cable Copper Conductor For Signaling / Mining Apply to low voltage circuit, remote control, security system, communication system and talkback etc. Fire Protective Signaling Circuits, Smoke Detectors, Strobes/Sirens, Pull stations Voice Communications, Burglar Alarms, Audio, Control, Initiating & Notification Circuits, Microprocessor/Addressable Controlled Systems. The products can be produce according to the standard IEC more
    Brand Name:Huanghe
    Place of Origin:China
    Certification:ISO OHSAS CCC

    Iec 60331 Fire Resistant Cable Copper Conductor For Signaling / Mining

  • China IEC 60331 Burning Testing Equipment For Electric / Optical Fibre Cables Circuit Integrity wholesale
    IEC 60331 Electric or Optical Fibre Cables Circuit Integrity Burning Testing Equipment Description: The tester is suitable for test electric and optical fibre under the flame not less than 750℃, whether keep circuit integrity under fire conditions. ... more
    Brand Name:HTI
    Model Number:HTB-046
    Place of Origin:Guangdong,China(Mainland)

    IEC 60331 Burning Testing Equipment For Electric / Optical Fibre Cables Circuit Integrity

  • China UL 3271 XLPE Hook Up Wire 600V/125C 18awg Ul758 Red Light Industrial Power Heater wholesale
    ... Fire resistant Will neither burn or support combustion. Comply with the requirements of IEC 60331 and BS 6387. High operation temperature Continuous operating temperature up to 250 °C, and for short periods up to approaching the melting point of copper ... more
    Brand Name:MYSUN
    Model Number:UL 3271
    Place of Origin:Shenzhen, China

    UL 3271 XLPE Hook Up Wire 600V/125C 18awg Ul758 Red Light Industrial Power Heater

  • China PH30 2×1.0mm2 Fire Alarm Cables PH30 Fire Resistant Cable wholesale
    ... wire, class 1,2 or 5 according to EN60228. Insulation: Fire resistant silicone rubber BS 6387 CWZ,EN 50200 PH30,IEC 60331 Dia.over Dielectric:2x(0.087"(2.2 mm)) Insulation Color: Blue / Brown Shield 1: PET Foil Drain Wire: 0.80 ... more
    Brand Name:Zion communication OR OEM
    Model Number:EN50200 PH30 Cable
    Place of Origin:China

    PH30 2×1.0mm2 Fire Alarm Cables PH30 Fire Resistant Cable

  • China YJV22/YJV Hv High Voltage Power Cable Steel Belt Armored N2XRY STA  Underground Use wholesale
    ... sheath: PVC Over Sheath: PVC Rated voltage: 6/10kv 8.7/15kv 12/20kv 18/30kv 21/35kv 1. Standard IEC 60502, 60228, 60332, 60331 DIN VDE 0276-620 HD 620 S1: 1996 DIN more
    Brand Name:DONGJIAXIN
    Model Number:YJV, YJV22
    Place of Origin:CHINA

    YJV22/YJV Hv High Voltage Power Cable Steel Belt Armored N2XRY STA Underground Use

  • China Marine XLPE insulated DNV LR Certified Shipboard electrical Cable wholesale
    ... Shipboard Cable 0.6/1kv SPECIFICATION & STANDARDS IEC 60288 IEC60092-351 IEC60092-376 IEC60092-359 IEC60332-1 IEC 60331 Construction: 1. Conductor: tinned copper 2. Insulation: EPR 3. Tape 4. Individual screen: tinned copper wire braided 5. Tape 6. Inner ... more
    Brand Name:CCME
    Model Number:CCM3
    Place of Origin:Jiangsu

    Marine XLPE insulated DNV LR Certified Shipboard electrical Cable

  • China Charging Cables for Electrical Vehicles 300V H07BZ5-F 62893IEC123 wholesale
    ... range:-40℃~90℃ Rating voltage:AC 450/750V/DC 1000V Reference standard:EN 50620:2017,IEC 62893-3:2017 Flame Test:IEC 60331-1-2 Min Bending radius:6xD more
    Brand Name:ECHU
    Model Number:H07BZ5-F 62893IEC123
    Place of Origin:China

    Charging Cables for Electrical Vehicles 300V H07BZ5-F 62893IEC123

Tell “iec 60331 1” Suppliers Your Requirement
*E-mail:
* Message:
Characters Remaining: (0/3000)
Inquiry Cart 0