Categories | Stationary Power Source |
---|---|
Brand Name: | GENY |
Model Number: | YCS-103 |
Certification: | ISO, CE |
Place of Origin: | China |
MOQ: | 1 |
Price: | negotiate rates |
Payment Terms: | T/T,L/C,D/P,T/T |
Supply Ability: | 5 sets / 1 months |
Delivery Time: | 6~8weeks |
Packaging Details: | Plywood cases |
Test voltage output: | 3×(24V – 288V) or customized |
Power of the voltage output: | 3×100VA/3×250VA/3×500VA/3×1000VA |
Test current output: | 3×(1mA – 100A) |
Phase angle range: | 0 -- 360° |
Relative humidity: | 35% -- 85% |
Ambient temperature: | -10°C -- +40°C |
Voltage Supply: | 3×220/380V±10% or customized 50/60Hz±2Hz |
>
Max 21 Times Harmonic Free High Precision Three Phase Energy Stationary Power Source
Parameter | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
Voltage | ||||
Test Voltage Output (Phase-Neutral) | 3×(24V – 288V) or customized | 3×(24V – 288V) or customized | 3×(24V – 288V) or customized | 3×(24V – 288V) or customized |
Power of the Voltage Output | 3×100VA | 3×250VA | 3×500VA | 3×1000VA |
Resolution | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range |
Setting Accuracy | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value |
Stability | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) |
Load Regulation from 0-max. Load | < 0.01% | < 0.01% | < 0.01% | < 0.01% |
Distortion Factor | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load |
Harmonics (2nd – 21st) | Free programmable | Free programmable | Free programmable | Free programmable |
Current | ||||
Test Current Output | 3×(1mA – 100A) | 3×(1mA – 100A) | 3×(1mA – 100A) | 3×(1mA – 100A) |
Power of the Current Output | 3×150VA | 3×350VA | 3×750VA | 3×1500VA |
Resolution | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range |
Setting Accuracy | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value |
Stability | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) |
Load Regulation from 0-max. Load | < 0.01% | < 0.01% | < 0.01% | < 0.01% |
Distortion Factor | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load |
Harmonics (2nd – 21st) | Free programmable | Free programmable | Free programmable | Free programmable |
Phase Angle | ||||
Range | 0 -- 360° | 0 -- 360° | 0 -- 360° | 0 -- 360° |
Resolution | 0.01° | 0.01° | 0.01° | 0.01° |
Setting Accuracy | 0.1° | 0.1° | 0.1° | 0.1° |
Frequency | ||||
Range | 45Hz – 65Hz | 45Hz – 65Hz | 45Hz – 65Hz | 45Hz – 65Hz |
Resolution | 0.01Hz | 0.01Hz | 0.01Hz | 0.01Hz |
Voltage Supply | ||||
Voltage Supply | 3×220/380V±10% or customized | 3×220/380V±10% or customized | 3×220/380V±10% or customized | 3×220/380V±10% or customized |
Frequency | 50/60Hz±2Hz | 50/60Hz±2Hz | 50/60Hz±2Hz | 50/60Hz±2Hz |
Operating Conditions | ||||
Ambient Temperature | -10°C -- +40°C | -10°C -- +40°C | -10°C -- +40°C | -10°C -- +40°C |
Relative Humidity | 35-- 85% | 35% -- 85% | 35% -- 85% | 35% -- 85% |
*If you want to know more please check our official website:http://www.genymetertestequipment.com/
![]() |